Our Product types >> Consumable >> ESD DISSIPATIVE SLEEVING

ESD DISSIPATIVE SLEEVING

 

BENEFITS

-Permanent Static Dissipative
-Insensitive to environment
-Special design for cleanroom application

STOCK AVAILABILITY (SLEEVING FOR WIRES & ETC)

Inner Diameter (mm) Outer Diameter(mm) Standard Roll (Meter) Part No.
3 3.8 100 ESD 030 / 038
6 6.8 100 ESD 060 / 068
10 10.8 100 ESD 100 / 108
15 15.9 100 ESD 150 / 159
28 29 5m ESD 280 / 290
31 33 5m ESD 310 / 320
40.5 43 5m ESD 405 / 430

Specification

Surface Resistivity 8 * 10 to power of 8
Decay time at centre of tube 0.5 to 1.2 seconds
Decay time at end of
tube
0.8 to 1.3 seconds
Float voltage observed 0V to 3 V
Peel off voltage observed 0V to 3V
The Sleeving are free from silicon

RESULTS:
OUTGASSING – Below are the data obtained from using the following chemical

COMPOUND INDENTIFICATION Section 1 Sample Section 2 Sample Section3 Sample Average
BHT 13ug/g 12ug/g 13ug/g 13ug/g
KETONES 25ug/g 27ug/g 23ug/g 25ug/g
SILOXANE 0ug/g 1ug/g 0ug/g 1ug/g
HYDROCARBON, OTHERS 16ug/g 15ug/g 19ug/g 17ug/g
TOTAL 54ug/g 55ug/g 55ug/g 56ug/g

FTIR / SILICONE OIL / HYDROCARBONS

– Below shown was obtain from the analyzed results on one section of the Sleeving.

Section 1 Sample Limits
SILICONE OIL 9 As per customer’s specification
HYDROCARBONS 158 As per customer’s specification

Note: Results for both the silicone oil and hydrocarbons are in nanograms/cm square surface area.

IONIC CONTAMINATION – The results tested as follows

 

SAMPLE Section 1 Sample (ug/cm square) Section
2 Sample
Section
3 Sample
Average Limits
(ug/cm square) (ug/cm square)
AMMONIUM 0.017 0.018 0.015 0.017 As per customer’s specification
BROMIDE 0.007 0.008 0.004 0.006
CALCIUM 0.022 0.02 0.02 0.021
CHLORIDE 0.01 0.009 0.011 0.01
FLUORIDE 0.03 0.031 0.03 0.03
MAGNESIUM 0.001 0.001 0.001 0.001
NITRATE 0.003 0.003 0.004 0.003
NITRITE 0 0 0 0
PHOSPHATE 0.078 0.08 0.07 0.076
POTASSIUM 0.01 0.01 0.011 0.011
SODIUM 0.154 0.152 0.147 0.151
SULFATE 0 0.004 0.001 0.002
TOTAL SUM OF ANIONS 0.332 0.336 0.314 0.327

ROHS FOR SLEEVING

On analysis, the following result were obtain:-

Test Parameter Digestion/ Extraction Method Analysis Method Result,ppm
(w/w)
Mercury (Hg) AC/RoHS/0010 Ver1.1/05 Wet Acid Digestion (Microwave) CVAAS ND
Lead (Pb) AC/RoHS/0007 Ver1.0/05 Dry Ashing ICP-AES ND
Cadmium (Cd) AC/RoHS/0007 Ver1.1/05 Wet Acid Digestion (Microwave) ICP-AES ND
Hexavalent Chromium (Cr6+) Ac/RoHS/0011 Ver1.0/05 EPA 3060A / 7196A (Modified) ND
Polybrominated Biphenyls (PBB) AC/RoHS/0012 Ver1.1/05 (Microwave) GC-MS ND
Plybrominated Diphenyl Ethers(PBDEs) AC/RoHS/0012 Ver1.1/05 (Microwave) GC-MS ND